Features and advantages
l Supports Modbus RTU protocol
l Supports connecting RS485 serial port for upgrade
l Supports 1 temperature acquisition, and retains one decimal digit when the screen displays the acquisition results in degrees Celsius (℃). The measurement range is-20.0℃~75.0℃, and the typical accuracy is ±0.3℃@25℃
l Supports 1 humidity acquisition, and the screen displays the acquisition results with one decimal number retained in percentage form (%). The measurement range is 5~95% RH, and the typical accuracy is ±3.0% (20%~80%RH@25℃)
l Supports 1 dew point temperature acquisition, and retains one decimal digit when the screen displays the acquisition results in degrees Celsius (℃). The measurement range is-40.0℃~75.0℃, and the typical accuracy is ±0.3℃@25℃
l Supports custom setting of temperature and humidity upper limit alarm threshold and temperature and humidity lower limit alarm threshold. When the specified threshold is exceeded, an alarm point value will be generated
l Support mechanical button setting, easy to operate
l Support the function of button lighting up the screen (backlight), which is clear and intuitive
Technical parameter
Essential information
Processor | Arm |
Embedded operating system | Rtos |
Communication parameters
Communication port | 1 rs485 interface |
Interface form | Phoenix terminals |
Protocol | Modbus rtu |
Overvoltage and overcurrent protection | 5v/200ma |
Lightning protection | 600w surge |
Forms of protection | Pptc+tvs |
Acquisition parameter
Temperature range | -20℃~75℃ |
Temperature accuracy | ±0.3℃@25℃ |
Number of channels | Route 1 |
Humidity range | 5%~95% rh |
Humidity accuracy | ±3%rh(20%~80%rh@25℃) |
Number of channels | Route 1 |
Long term stability
Temperature | <0.1℃/y |
Humidity | <1%rh/y |
Response time
Temperature | Less than 5s (1m/s wind speed) |
Humidity | ≤ 10s (1m/s wind speed) |
Power parameters
Input power supply | 9~27v dc |
Power dissipation | <10ma@12v dc |
Overvoltage and overcurrent protection | 30v/200ma |
Lightning protection | 600w surge |
Forms of protection | Pptc+tvs |
Protection and protection |
|
Protection and protection
Emc | Static electricity: Gb/t 17626.2-2018, level 2, contact 4kv, air 4kv |
Work environment
Working temperature | -20℃~75℃ |
Working humidity | 5%~95%rh (no condensation) |
Size and installation method
Size (mm) | 86*86*24.2mm |
Way to install | Installation of positioning holes |